Skip to main content

rTMS equipment

Brainclinics solutions

Our experience and expertise with rTMS* in clinical practice and research is unmatched. Since 2006, we pioneered the technique in the Netherlands and have since then refined and advanced our knowledge and expertise to the point of perfection. We have seen equipment evolve over time, from ‘vacuum-cleaner’ based TMS cooling devices, via blown-up stimulators and the dTMS head-mounted coils to the highly portable TMS systems we can carry around for easy demonstrations. Furthermore, we’ve been instrumental in the development of new innovative TMS approaches such as Heart-Brain Coupling, and always keep the patient-perspective in mind.

We have experience with all major TMS systems and never shy in engaging with manufacturers when it comes to improving their equipment.

Our feedback matters, manufacturers listen. And we listen to you.

More information?
The devices that we work with are best-in-class, and of course they’re medical CE approved. All systems we recommend are capable of standard rTMS protocols (HF or LF TMS) as well as iTBS. Furthermore, devices can be used for DLPFC stimulation as well as more experimental protocols such as OFC-stimulation using double-cone coils.

If you are interested to apply rTMS in your own practice, or have further questions, please contact us for advice, and of course we’d be happy to provide you with a quotation too.

Would you like a training package tailored to your needs? We’ve got you covered!

 

* What is rTMS?

rTMS stands for repetitive Transcranial Magnetic Stimulation or brain stimulation in short. When applying rTMS, a coil is put at a precise and particular location on the head. The strong magnetic field generated by the coil is converted into pulses which exit the device and then easily penetrates through the skull to reach the brain. These strong magnetic pulses can stimulate specific parts of the brain and can help normalize connectivity within specific functional networks that are implicated in for example mood or compulsions as seen in depression or OCD. For more detailed information about how rTMS works, and for what indications it can be used also our rTMS review. More information about combined rTMS with psychotherapy can be found here.

Deymed DuoMag rTMS Stimulators

Deymed has become an established worldwide leader in neurology and psychiatry for both clinical and research applications. Their aim is to develop products that meet and exceed the highest standards in neurology. High signal quality, ease of use, portability and reliability are the hallmarks of Deymed systems.

Deymed rTMS stimulators stand out by their highly innovative drive and modern design of stimulators, where extra attention is paid to ease of use, such as the counter-balanced lockable coil holder, unique to the Deymed stimulators. At the same time, Deymed stimulators have a competitive price:quality point.

This equipment has been developed recently and is based on the latest technical insights.
The DuoMag rTMS equipment can be used for different rTMS treatment protocols as well as scientific research. There are 3 models to cover your needs. In general, these are all rTMS devices with a bi-phasic pulse. You can download the brochure here.

DuoMAg XT-10

Product Specs DuoMAg XT-10
Pulse modus Bi-phasic, repetitive
Dimensions 49x16x38cm
Weight 17kg
Stimulation intensity 100% 5Hz
Stimulation intensity 50% 10Hz
Max. repetitive rate 20Hz
Min. interstimulus interval in trainmodus 1ms
Pulse width 290μs
Coil compatibility Deymed coils
Voltage 100-240Vac 50/60Hz
Synchronisation TTL in/out and/or USB
Communication USB full control on coil

DuoMAg XT-35

Product Specs DuoMAg XT-35
Pulse modus Bi-phasic, repetitive
Dimensions 49x16x38cm
Weight 17,5kg
Stimulation intensity 100% 13Hz
Stimulation intensity 50% 35Hz
Max. repetitive rate 50Hz
Min. interstimulus interval in trainmodus 1ms
Pulse width 290μs
Coil compatibility Deymed coils
Voltage 100-240Vac 50/60Hz
Synchronisation TTL in/out and/or USB
Communication USB full control on coil

DuoMAg XT-100

Product Specs DuoMAg XT-100
Pulse modus Bi-phasic, repetitive, burst
Dimensions 49x16x38cm
Weight 17,5kg
Stimulation intensity 100% 22Hz
Stimulation intensity 50% 80Hz
Max. repetitive rate 100Hz
Min. interstimulus interval in trainmodus 11ms
Pulse width 290μs
Coil compatibility Deymed coils
Voltage 100-240Vac 50/60Hz
Synchronisation TTL in/out and/or USB
Communication (No value provided)

 

MagVenture MagPro stimulators

Deymed has become an established worldwide leader in neurology and psychiatry for both clinical and research applications. Their aim is to develop products that meet and exceed the highest standards in neurology. High signal quality, ease of use, portability and reliability are the hallmarks of Deymed systems.

Deymed rTMS stimulators stand out by their highly innovative drive and modern design of stimulators, where extra attention is paid to ease of use, such as the counter-balanced lockable coil holder, unique to the Deymed stimulators. At the same time, Deymed stimulators have a competitive price:quality point.

This equipment has been developed recently and is based on the latest technical insights.
The DuoMag rTMS equipment can be used for different rTMS treatment protocols as well as scientific research. There are 3 models to cover your needs. In general, these are all rTMS devices with a bi-phasic pulse. You can download the brochure here.

MagPro R20

Product Specs MagPro R20
Pulse modus Bi-phasic
HxWxD (mm) 150x390x440
Weight 20kg
Ramp up no
Max. repetitive rate 20 pps
Voltage 230V~, 50/60Hz
Power consumption 800VA

MagPro R30

Product Specs MagPro R30
Pulse modus Bi-phasic, Theta Burst*
HxWxD (mm) 210x530x400
Weight 36kg
Ramp up yes
Max. repetitive rate 30, 60*, 80* pps
Voltage 230V~, 50/60Hz
Power consumption 2700VA